Single-phase bipolar grounding LBM-10-III leakage protection plug (PRCD) instruction manual
Self-declaration no. :2020970306000037
Implementation standards:GB/T20044-2012
一、Product appearance picture

二、 Before each use
1、Before using this product, please check the electrical appliances, make sure there is no abnormal before connecting to the power supply.
2、Press PRCD“Reset” button, power indicator light, then press“Test” button, product trip, power indicator lights off, repeat twice, the product can be put into use.
三、Points to note
1、The specification of the matched power socket must match with the specification of this plug, and must have 3c-certified fixed socket.
2、The plug should be installed indoors or in other locations to meet the requirements of waterproof.
3、The power supply socket shall be provided with a reliable grounding system.
4、Press PRCD“Test” button, power off, should immediately stop using.
5、Electrical leakage, bad socket leads to high plug temperature rise will immediately power off.
6、In case of thunderstorm, please disconnect the power supply to prevent lightning damage to this plug.
7、At the same time contact phase, zero line or phase, zero line short circuit, PRCD will not trip, and will cause danger.
8、Be sure to unplug this plug when repairing electrical appliances.